LX2000/1000 prints but the PTStatus (status monitor) says offline
- Ensure the SWFWClient.exe file is located in the installation folder. C:\Program Files\Primera Technology\Primera Color Label 2000\Bin
- Make sure SWFWClient64 client is running.
- Ensure Windows Firewall or other firewalls are not blocking this
program from being installed.
- If you manually copy this file from this location to the location above, you may be prompted by your firewall to allow the file to be installed. Once copied, double-click the file to run it. You will not see any user interface as this file runs in the background and is normally automatically started by PTStatus.
- Download SWFWClient.exe
- This exe program is the bridge between
the status monitor and the printer. It copies XML files to C:\Users\<currentuser>\AppData\Local\Temp If it is working properly, you will see status xml files constantly updating to this temp folder location.